Refer to the wiring diagram on the timer door for more information. After a few days its off by 6 or 7 hrs but still turns on and off fine any suggestions? To do this, pull the yellow-faced time dial (clockface) toward you. You can turn the dial and then only wait a few minutes to check is the OFF tab is working. It has 4 screws below the dial labeled from left to right: LINE 1, LINE 2, LOAD 1, LOAD 2. Hello. The position of the metal bar forces the gear next to it to turn one way or another. It is a good idea to use pliers or a wrench and reseat the trippers, then tighten them at the desired on/off times. The problem I am having is the timer clock moves correctly, but when it gets to the ON or OFF mark it stops and does not make the switch turn ON or OFF. Commonly, many pool owners will think there pool timer is broken and not working when all they had to to is turn the circuit breaker to the on position. Hi Cody, if you cannot see any obstruction in the motor gears, or any such mechanical issue, then I would assume an electrical issue, perhaps the wrong voltage for the clock. Is it possible to do this by loosening the timer screw a bit? You can turn that yellow dial by hand CW to see if the trippers hit the off and on switch and to set the time on it. IT happens, so I ask. When I turned it back on now the pool clock goes backwards. Assuming the wiring is all correct. Elite. I would shut off power to the clock while you spray, and release the tab at the top so you can spray behind the clock, and then find the nearby nest, and dig it up and add in some ant killer granular, or other method, to get the colony to move somewhere else. Gears are moving , clock is seated correctly and everything is wired per diagram now that pool season is here I have to manually turn my pool on and off at the timer . Common timer problems include the clock not turning, not switching the pump on/off, loose timer pointer and a stopped clock. Please let me know if you find the solution! The pump worked perfectly before I unscrewed it. I found a diagram showing neutral to A, line 1 to terminal 1 and line 2 to terminal 3. Eldon, the breaker should not be bad, but the timeclock may be wired incorrectly. I have an Intermatic t104. Pool and Spa Expert: Mike_G2010 With the switch up it is in Auto mode. Any suggestions? I looked through the visual motor check and the gear still moving fine. "thumbnailUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
But of the timer itself is bad you will need a licensed electrician to change the timer for you. Just some ideas. I have a T103 24 hour dial time switch and noticed the time was off so not reading the DO NOT UNSCREW on the pointer I unscrewed it and moved the pointer to the right time and screwed it back tight. There is no replacement on/off switch available, you would need a new T104 mechanism, unless you are able to melt some solder, or fix it with duct tape or something, lol! If I manually push the lever, it moves without much pressure. There are many reasons why your pool timer may not be working. "wordCount": "1259",
When the power goes out, the timer stops. But first, pull the mechanism from the box by releasing the tab at the top (be sure breaker is turned off, first), and inspect the gears and copper tabs on the back, to look for something clogging up the works, insects, lizards, sand, etc. Thanks Reid. I am having the same problem. Flip it from where it is now, to the opposite side. There is a switch control panel and replaced the 20amps DP switch as well. Hey there! HELP! How can I fix this? You can always call us at 815-675-7000 M-F 8am-4:30pm CST and . Hi Carlos, is there a GFCI outlet in the circuit? Hi Agnes, have you tried using a cover pump to remove the rain and/or snow melt from the cover? The A terminal is not normally used, unless you have a 3 wire service. They may be fused together, or could be a lizard stuck in there, or some other foreign object or insects. This pool timer is waterproof, heavy-duty, and accurate. The pool timers I have had down there . Articles and resources for swimming pool owners and DIYers. But if your circuit breaker is in the on position and your pool timer clock is not rotating and the timer is not working then you will need to call a licensed electrician to replace the timer. Keeping a pool operational is expensive enough anyway, so every saving you can make helps. I replaced a bad timer (90% sure I put the wires in the correct/same spots but there was one time when two wires got loose, so its possible I wired it wrong) and now it turns on and works, but the on/off switch doesnt work. Pump operates off schedule Power failure earlier Reset timer Breaker was OFF for some time Reset timer 4. Hi Catherine, turning it on manually should not have damaged anything, so go easy on yourself It might have just been time to go. If dial is rotating correctly, but water heater never turns on-off, then trippers might be bad. My pump has a plug. It randomly loses the time that it is set to. Generally the power goes from the breaker > Timeclock > pump, so that the power is always on to the clock. Replace a new T104. Hi, Also be careful not to loosen the timer pins to much or they could fall off the timer wheel and onto the ground. You can manually engage it by turning it and then it will run and even SHUT OFF when its supposed to. The power should run from the breaker, to the timer, to the pump. This product is certified by Amazon to work with Alexa. Video of the Day Trippers If you look closely, you should be able to discern if this is the problem, which could mean a new clock. If its not, then the timer will not turn on/off at the correct times. It is an ON tripper right? Problems with Intermatic timers are caused by defective trippers, incorrect wiring, tripped circuit breakers, a faulty time clock motor and incorrectly set power terminals. I have the Intermatic T103 autotimer on my pool. PF1202T Freeze Protection Control Parts - INYOPools.com Home Pool Parts Time Clock & Control Parts PF1202T Freeze Protection Control Free Shipping on all Orders over $49! It should be 110V or 220V AC. Does the tripper work on other areas of the clock, like near the off tripper? As an Amazon Associate we earn from qualifying purchases. Either that or if an older clock, the motor may be failing, or the switch mechanism worn (the part that is tripped by the tripper). Or may be bent and not come together. Does this give you a better idea of the problem? Another time clock that you can plug your pump directly into, and then plug the timer into the outlet, is the 24-hr Timer https://www.intheswim.com/p/24-hour-pump-timer (currently we are out of stock, but you can find at any home or hardware store). It is twisted clockwise or counterclockwise until the correct current time lines up with the "Time" marker, which points directly downward at all times while the clock dial constantly turns. I have a T104. However the new breaker is in a constantly tripped position. Hi Jennifer, power down (shut off the breaker) again, to see if it will switch back. Intermatic timers are a great addition to your pool set up but they can go wrong. Im sure I hooked it up correctly but when running it gains a little over an hr of time every 24 hours. I went to my houses main panel breaker and Flipped that breaker which leads to the pool panel breaker and replaced that breaker which goes straight to the timer. I would check that the motor says 60 hz on it and they did not send you a 50 hz by mistake. Pool Timer Not Turning ON or OFF!! Turn the metal bar until it contacts one of two plastic side tabs. Align the bar with the current time and push it back into place. The timer motor cover (the oval silver box with the printing) can be pried off with a sharp screwdriver. I have a 2 speed pump. Below is a breakdown of how to wire different Intermatic timer models. Simply screw it back into place until its snug. Look for any disconnected or damaged wires leading to the motor on the rear of the clock. Hello. There should be an off pin and an on pin. The instructions say THIS TIMER IS NOT TO BE USED AS A POWER DISCONNECT. No broken or loose wires visible. Wont power on pump but can hear timer clicking away. A power surge may have taken out the timer or the pump. I have a PF1112T. There is power; gears are moving. Sometimes the trippers get loose or damaged. "image": {
Use Green ON tripper for T100 Series timers and the silver ON tripper is for all other models. How about the GFCI outlet TEST button, is it tripped? OPEN TODAY, 12PM TO 3PM. How can it keep time if lever is in off position (manual lever). Hi Fred, the only thought I have is that the cord should not be unplugged to turn off the pump, instead, rotate the dial until it turns off, because I dont believe there is a switch to turn off the timer. I had to replace my 2 year old intermatic timer motor this season as gears werent turning. You will first want to look at the pool timer and see if you have two timer pins. So just turn the adjustment hold down screw on the timer pin counter clockwise about a full turn and then you will be able to slide the on or off pin to the right time on the timer wheel. but ythe costs for T104 models vary greatlyHave ahayward 1 1/2 horsepower pump inground pool in Fl. Sometimes those are looped back to the control box. Theres really only 3 causes as to why your pump wont turn on/off. So either the tripper is broken (or installed out of alignment) or the tab (s) on the on/off switch are broken. Hi Phil, usually the OFF dog may not be fully pushed onto the dial, or if you examine it closely, it might be worn. Gas pool heaters are one of the best additions to a pool, but they are the most high-maintenance piece of equipment on, 22,000 pool parts in stock! Check the diagram on the box label, and connect the wires from the breaker to the terminals marked Line, and the wires that go to the pump connect to the terminals marked Load. We like that this pool timer because it is made from heavy-duty material and two grounded outlet makes it safe and durable. how do I check the manual over ride switch to see if it is off? 3. Replace the gears if this is an issue. Check the wire connections to be sure they are tight, and look for any burnt wires. I unscrewed the clip and put it back on and its still doing the same thing. Other problems causing this could be the yellow clock dial isnt located correctly, wiring is loose, the gears are stripped, damaged or partially jammed or even the clock motor. No Power to the Timer Having no power to your pool timer is a common problem and will occur because of three reasons: The Circuit Breaker has tripped. I have an Intermatic 277/208v T104 timer controlling two 60Hz 120v outdoor lighting circuits. Intermatic 156T1978A Timer Switch Trippers, Intermatic Timer Parts Replacement for T100 Series and Intermatic Time Clocks T101, T102, T103, T104, Pool Timer On Off Clips(4 ON / 4 Off / 8 Screws) : Amazon.com.au: Home Improvement Move the switch and see that they separate when off, and come together when on. Other causes include rusted springs, insect infestation and loose timer dogs. DEWENWILS Outdoor Outlet Box. The 120V or the T101 model has 3 brass screws (terminals) underneath the plastic insulator cover. The time does not advance after resetting. If the timer manual switch isnt jammed and freely moves into the On and Off positions, then there is either no power to the timer, the timer itself has a fault, there is an issue with the wiring or the pool pump is faulty. After securing the wire conduit (flexible or rigid) to the box, knock out with the proper 3/4 conduit connector. Hi Jerry, it could be that the lubricant is gone, or needs more lube on the switch. I looked to see if the gears on the timer are running. Hi there, Is there anything else I can do or do I need to get a new one? If there is still no movement, test the wires coming into the time clock to see if power is reaching the time clock. "@context": "https://schema.org/",
Is it Necessary? },
Then number(time of day) that you line up with the time marker will be the time that you are setting your timer to. Now, Im going to order some additional timer clips. Did you find the issue? the trippers are even slightly damaged the timer won't work correctly. If you dont have the voltage here you have an issue with either the wiring or the breaker. Once you remove the water, you can use your pool brush on a pole, to gently push the pillows back to the center. Read Book Tork Trippers Manual Guide Pdf For Free Sea Kayaking The World Almanac Road Trippers' Guide to National Parks: 5,001 Things to Do, Learn, and See for Yourself Dream Trippers The Little Road Trip Handbook Technical Manual War Department Technical Manual Canadian Mining Journal. Sound right? Also be sure that the front dial is engaged with the gear located behind the dial. You will feel the wheel pull out about an 1/8 of an inch and then you will be able to rotate the timer wheel. You can replace the entire mechanism or the gears. You need extreme care in this next step. These clocks determine when your pool pump turns on, and how long it runs. Also known as an RCD (residual current device) in Australia and the UK. Grab your torch and shine it in the holes. Morgan Burley The most common pool timer used for inground pool pumps is the Intermatic time clock. My intermatic timer is about two years old as well. Save my name, email, and website in this browser for the next time I comment. Hi Tyler, maybe the dial is now pushed forward, far enough to where the trippers do not contact the switch? I have the same issue currently, and it makes no sense to me so far. I noticed one thing that the power from the breaker is going into the control panel. My timer doesnt seem to be working or my pump in either speed. If power is coming to the timer motor, you will clearly see the gears moving through the small window. Hi Jeremy, I would try to pull the unit out and clean it well with compressed air and then spray with WD-40 and see if that helps. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Ft. 750 Joshua Dr, Hollister, CA 95023. Hi, if you have a variable speed pump, you do not need to use the external timer anymore, but should program with the on-board pump timer. Set the current time to the center time pointer, pointing downward at 6 oclock. #9. Then after a bit, the pump restarts. $115 Providence distortion MIJ - $120 All working perfectly Should be clear in photos which include boxes, others will be bubble wrapped and . DEWENWILS Pool Pump Timer, Outdoor Smart Wi-Fi Box, Heavy Duty 40A 120-277 VAC 2HP Wireless Controller Timer for Pool, Water Heater, Compatible with Smart Phone, Alexa, Google Assistant, UL Listed. Before using your timer to optimize your pump, you need to determine that your pool's pH, alkalinity, and calcium hardness are 7.4 to 7.6, 100 to 150 ppm, and 150 to 400 ppm, respectively. The problem lies where the power dies, youve probably heard that before. The clock is powered from the Line 1 terminal correct? I have removed the ON TRIPPER and turn the motor on at the pump and it never trips the GFCI. Everythings OK now, unit works just fine. Can A intermatic timer for a pool be lubricated I have duel timers for a low and high speed jandy pumpIt seems it might be a little louder on the fast speed side. Having no power to your pool timer is a common problem and will occur because of three reasons: The first and easiest thing to check is the circuit breaker. The on/off pins are tight and pretty new stillany thoughts? Reference Manual & Buyer's Guide Another Brick in the If power is reaching the clock, but the motor gears are not turning, that usually means either something is jammed in the gears, or the timer motor has burned out. Help! Timer not tripping pump on. Pop-in a new timer mechanism, and replace the wires to the previous configuration. How to fix a Pool Pump Timer - Easy replacement using the Intermatic T104 Darren Does Everything Pool Timer Not Turning ON or OFF!! Now it worksbut its really fast. Paul, it could be that you got a 50hz motor, instead of a 60hz? Back when I was a young technician I was taught to always look for the easy things and use all my senses. I can, however, hear an intermittent click as if the mechanism is trying to switch on. Your pool timer and pump will be on its own circuit and have a dedicated circuit breaker or GFCI (ground fault circuit interrupter). }
. Learn more about pool care and repair. Wired correctly, #10 wire, nothing. Is there a separate switch somewhere between breaker and timer? You off course will want to adjust one time pin at a time. The pool was running on a timer. I have a inground pool with T10003RT4 control panel. I noticed that they had stopped. If still not working, check the wire connections and then test voltage on the clock incoming wires, outgoing wires, and then at the pump motor the problem lies, where the power dies, as they say. Hi Mike, yes I sent you an email to your yahoo acct. "address": "",
Thank you. The problem is the 'off' tripper. Most Intermatic timer parts can be renewed but sometimes you need to replace the whole mechanism. JACUSTOMER-hlvgjzll- : I have just sprayed WD-40 on the switch coils that move the lever that the trippers hit. Should I go ahead and spray it anyway? First, verify the power is turned off at the breaker panel. If you have both pins take notice of there position and then come back in a few hours and see if they have changed from the spot they were in when you last looked. Remove the plastic insulator cover, and use an AC test meter to check for power on the terminals where the wires from the breaker connect to the time clock. Any ideas? Analog timers are the simplest type of pool pump timer and are easy to use (and the cheapest). And does the switch look worn, where the tripper engages? March 16, 2022 by WildRiverCountry. Shannon, compare the wiring to the diagram for Line and Load (line is power coming in, Load is power out to your pump). Luis, it will, until it is switched to OFF, or until the OFF tripper shuts it off. To check this, carefully inspect the gears for missing teeth and make sure they all freely turn. Miriam, I would check that the timer dogs are pushed fully onto the dial, and the dial is tight also check the screw for tightness in the center of the dial. After a power failure the timer clock can start up backwards, mine has done this several times. I bought a new timer and replace the T104 timer clock. Ive got a weak pump battery so every time the mechanism shuts off it looses time. 110V or 220V? "name": "Davy Merino",
. Or there could be a bad relay in the control panel, if you have ice cube style relays. The problem was the connections I made inside my main electrical panel, I used romex wire nuts to attach the solid core #10 wire that I used to hook up the timer to the existing stranded #10 wire and it didnt make the connection so to speak. Terminal A (farthest to the left side) is not connected to anything. Just replace it and hope for one that isnt defective. Clean the gears with a toothbrush if you see debris or gunk in them. Is power reaching the time clock? Beverly, it could be, but the cost of running wiring to the garage may be more than replacing it every 15-20 years. The trippers push on a tab on the on/off switch. I replaced the fuse(BUSS 300v GLR 3) as well. Partially loosen the screw that holds the "off" pin in place. Also, does it sound like the power is not leaving the breaker? The rest of your setup is probably fine. Or might find something else. the timer was directly plugged into a gfci and the pump directly into the timer. Now The ice and snow have melted and the cover is getting in deeper. I have a intermatic T101 and the clock doesnt move I replaced the old one due to burned out motor . "width": "611",
"headline": "Intermatic Pool Timer Troubleshooting",
It I set the timer again it will jeep time until it gets to the next dog ear. About 1-2 years ago I swapped out this unit because it was sticking and not engaging when it was supposed to. "@type": "BlogPosting",
If your pool pump timer is beyond repair, call a professional to replace it. 2303 RR 620 S #135-378 Lakeway TX 78734 USA (737)-210-8494 Sign in or Register Compare Gift Certificates Advanced Search Search Keyword Required Categories Automatically search sub categories Brands Search By Price Price Range From to Search By Setting Still no luck. Proceed to step 4 to check the timer itself. Or if power is interrupted to the pool pad, for some reason, maybe breakers flipped off for some electrical work? Could be small bugs, or dirt, or both causing the problem. What do you suggest to do to get the cover up and the pillows back into position. },
I replaced T104 timer it runs and shuts off with no issue but once off the timer does not move or turn back on. Some white lithium grease on the switch can help in some cases. Ordered new ones. Is it keeping time normally? With the power switched off at the breaker, take out the main part of the timer and carefully inspect the gears for obstructions and missing teeth. I think I have found it. I bought a new motor for mine after 20 years and learned about this the hard way. Motor runs past the on dog but doesnt flip pump on? You can find this in your power board. There is also a light switch for the lighting in the pool in the control panel and when i turn on the switch the light in the pool turns on. "url": "https://blog.intheswim.com/"
Hi Tanya, yes that sounds like it might be wired incorrectly, check the wiring diagram on the label, or if missing, you can find them online for your timer model. I can manually turn it on with the lever at the bottom. 1100 Juanita St , Austin, TX 78704-5351 is a single-family home listed for-sale at $2,649,000. Replace the plastic insulator cover, turn on the power, and observe the visual motor check. Jump to the troubleshooting steps below to fix the issue. Could I send you a picture of my setup? Just turn the timer wheel until the correct time of the day is aligned with the timer marker that is mounted in front of the wheel. Another thing you will need to troubleshoot and check is the circuit breaker for your pool timer. It was always fine before. Your email address will not be published. I not sure if this is the best timer to use. Hello have a question some what related. Take a good look at the position of the pins and write down the locations. Switch the breaker off at the power board. Im wanting to use T101 to wire my above ground pool pump. GFCI breakers trip at a very low threshold, doesnt take much. After I replaced the motor with a 60Hz 277/208v motor the timer ran, but gained 1 hr/day. by pool co. , so wondered about the cost. If moving that is difficult, you could just avoid using the switch and turn the pump off with the timeclock instead, always keeping the switch on, and maybe taping the switch, to remind people not to use the switch. However, after several hours, maybe overnight, the associated breaker will trip. 1-48 of 242 results for "pool timer trippers" RESULTS. The same happens prior to the timer reaching the off tripper. You should be able to see the gears moving. Thank you. (For outside light timer) The one before was original to the house & I had no trouble. Ive seen it happen from lightning strikes, or insect infestation. If you loosen the hold down screw to much it could separate from the timer pin. I have a white, red, and black wire coming from the power source. Southern Queensland Country Tourism CEO Peter Homan says water park could convert 'day trippers' to overnight visitors to Toowoomba The region's peak tourism body has claimed a widely requested water park could increase Toowoomba's appeal to a new era of visitors, as council says a park was not a priority in the coming decade. Thanks for any help you can give. Should it still not work, I suspect a motor failure for the clock. Hi. },
Voltage is 243, frequency is 60hz. Hi Derrick, first try to reposition the timer tripper, making sure it is all the way on the dial. Trippers are not installed properly Re-install trippers on dial 2. With the breakers turned off, remove the mechanism from the box. Flip off the breaker. ft. home is a 3 bed, 4.0 bath property. Confused. And Ive noticed lately that the ON is not functioning all the time. More. Could also be grit or insects inside of the gears of the clock motor. 120Volt Tork 1101 timers can be fixed with repair parts. Thanks. Karl, good question. my pool timer the does not turn itself on only shuts off I put new trips in but still not working I dont see any ant build up inside there or anything could it just be time to replace the old girl because thats what Im thinking. I didnt check the connections because it seemed like an ordeal to take the timer apart to get to the wiring and I didnt want to make matters worse. However, intermittently after the ON tripper switches pump on the pump will stop. Intermatic timers can typically be fixed by checking theres power to the timer, resetting the time, renewing the ON/OFF trippers and renewing the gears or timer motor. I can turn the pool pump on via the manual power lever thats located at 5 O clock on the timer. My timer works good it turns on and off when I set the time. There's an issue with the wiring between the circuit breaker and the timer. Also, once it reaches the tripper, the gears in the window no longer move. Clock not turning or making any sound. As you release the dial, you will feel the gears engage. If power is reaching the clock, and the gears are turning, but the dial is not turning this means the gear on the back of the dial is not engaged. by Intermatic Technical Support | Jul 25, 2022 Helpful? Move the start and stop pins to appropriate times for swimming pool filter operation. Hi Dave, my pool timers not working but when I look in the little window I do see the largest back gear turning (possibly the yellow time plate gear as that appears to be moving..yet not keeping correct time.) It sounds like the Line and Load wires are reversed. Inspect the tripper portion, if it looks rounder or worn, replace them. It started lagging again a week or so ago. 4 Beds. It only takes a small amount of dirt to foul up gears so look carefully. Hi David, I suppose that you could wire the T101 from the outlet, but Im not sure if that is in accordance with code. Not two OFF trippers? This site is owned and operated by AJH Trade Group. I fastened it very securely. Hello, yes that sounds like you need the Intermatic T104 https://www.intheswim.com/p/2-circuit-pool-timer. After this has been removed, you can turn the breaker back on and measure for the voltage on the timer input. Same goes for slipping timer dogs! If you use our referring links, it costs you nothing extra. Did you try to flip the switch of the timeclock? Electrical Monke Aug 25, 2021 #22 It's broken. I hope this helps. If the power has gone out, your just opening your swimming pool for the season or some third reason, you may need to adjust the time on your Intermatic swimming pool timer. Should You Get a Pool Pump Timer? Just moved into my house and the pool pump continues to run even after tripping the timer mechanism. I made sure the trippers were fully inserted and tight. Theres power to the pump using the manual override. The timer switch has a solid click between trying to turn it on and off but since no power is going to the timer I get no juice tot he motor. not sure what is the problem. do i need to do something different? "height": "219",
Hi, I got the same problem as my clock not working. A qualified person would check there is power to the timer and then bypass the timer to see if the pump worked. "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
The dial turns, but when it gets to the trippers, both now, the dial stops & there is no sound the gears are working I am not an electrician but I can do small repairs. Hi Alfred, I would guess that either the time dial is bent, or that the larger gear behind the dial is missing a tooth, at 10 pm, or has a bit of grit stuck in the gear at that point. Im going to try inspecting the back of the timer to see if a wire go knocked loose or something. Hello Davy, Terry here again. That way I could schedule the pump once again. If you are not sure if your timer is working or not you will first need to know if its even operational. Is the ON tripper all the way pushed onto the dial? If unsure, the White (Neutral) wire connects to the neutral buss bar in the breaker panel, and the Black (Line) wire would connect to the circuit breaker. Sometimes the on/off switch on Intermatic and other mechanical timers can get tight.